HUMAN TECHNOLOGY FUTURE

Special company who focus on developing & manufacturing physical therapy and rehabilitation devices

TENS

TENS

Feature

Transcutaneous Electrical Nerve Stimulation, or TENS for short, was developed in the 1970s according to the pain gate control theory. It is a non-invasive treatment method that injects specific low-frequency pulse currents into the human body through the skin to treat pain. After more than 20 years of development, TENS is very popular in European and American countries, and its clinical application has gone beyond the scope of pain, but it still focuses on the treatment of pain. Become the most basic way to solve pain without taking medicine and without injections. 

How it works: The transcutaneous electrical nerve stimulator is powered by a current of appropriate intensity and frequency. Continuous, gentle stimulation of nerve and muscle cells, stimulate the body to produce morphine,Block pain information and relieve pain. In recent years, the application of percutaneous nerve stimulation therapy is no longer limited to the function of pain relief, but a small amount of current similar to the human body can also stimulate tissue regeneration. TENS does not guarantee complete pain relief, and the percentage of patients with pain relief varies, but in general, the relief rate for acute pain is around 65% and for chronic pain around 50%. But these methods are stronger than medical placebos, which are non-invasive and have few side effects compared to drug treatment. The most common problem is an allergic skin reaction (about 2-3% of patients), which is almost always caused by the electrode material, the conductive gel, or the straps that hold the electrodes in place.

INQUIRE

Specification

SPECIFICATION


1.Pulse curent: The pulse output peak currentis adjustable from 0mAto 100mA under the load of 1K0,the step size is 1mA,and the tolerance is±30%.

2.Pulse frequency: The output pulse frequency of the therapeutic apparatus is adjustable from 1Hz to 160Hz,the step size is 1Hz,and thetolerance is±10%.

3.Pulse width: The output pulse width of the therapeutic apparatus can be adjustedfrom 20us to 500us,the step size is 10μs,and the tolerance is±20%.

4.Timing function: The therapeutic apparatus has an output timing function,which is continuousy adjustable from 1min to 99min,with a steplengthof 1min and a tolerance of ±2min.

5.Pulse power: When the output of the therapeutic aparatus s under the condition of 5000 load,when the output amplitude is the largest,thesingle pulse power is not less than 2μC.

6.Pulse energy: The maximum output energy of a single pulse is not more than 300mJwhen the output of the therapy device is under the conditionof a load of 5002.

7.Short-circuit and open-circut test of the therapeutic device: After the output of the therapeutic device is tested foropen-cicuit and shortcircuit, its performance will not be impaired.Maximum peak voltage must be no greater than 500V when measured under open circuit conditions.


fb0fc0086ad0b7f2d7557fc3ed30104.png

96165fc3fd8d9f26dc1d75181f15395.png

aff25e5f35613d1ca4d51fe4559eecd.png

ad6fa7b80b1ed2d532a9c8e5f7689c9.png


Details

a89990233291fd8db4e90910c52d1f1.png

0f81b7c5c07b19e38f141cbffc93319.png

f471ee85c0e163698214b2d914fe0fb.png

a06c817598bb4bbc7df1bf8fc12ced6.png

Certificate

MESSAGE

SEND